35kV 3-Phase 2-Winding Power Transformer

The 35kV oil-immersed power transformer has the advantages of low loss, low noise and high efficiency, which can achieve good energy-saving effects and reduce pollution. The transformer is isolated from the air to prevent and slow down the deterioration of oil and insulation aging so as to enhance operational reliability, and maintain normal operation without maintenance.
Send Inquiry

Product Introduction

Part Ⅰ: 35Kv Power Transformer Overview

The 35kV oil-immersed power transformer has the advantages of low loss, low noise and high efficiency, which can achieve good energy-saving effects and reduce pollution.

The transformer is isolated from the air to prevent and slow down the deterioration of oil and insulation aging so as to enhance operational reliability, and maintain normal operation without maintenance.


35kV 3-phase 2-winding Power Transformer

Product Attributes

Model No.


Application

Power

Coil

Core-type Transformer

Frequency

50/60Hz

Phase

Three

Cooling Method

Oil-immersed Type Transformer

Capacity range:

630kVA-63000kVA

Operating Ambient Temperature

+40 °C--30 °C

Operating Altitude

≤1000m

Operating Max Wind Speed

≤35m/s

Earthquake acceleration

horizontal acceleration ≤0.3g

vertica I acceleration ≤0.15g

Standard

IEC 60076-1:2000, IEC 60076-2:1993, IEC 60076-3:2000, IEC 60076-5:2006, IEC 60137:2003; ANSI, IEEE, AS, etc.

Supply Ability & Additional Information

Packaging

Seaworthy Packing

Transportation

Ocean

Supply Ability

High

Payment Type

L/C, T/T

Delivery Time

60 Days

Place of Origin

China

Port

China Sea Port

Incoterm

FOB, CFR, CIF

Packaging & Delivery

Selling Units:

Set/Sets

Package Type:

Seaworthy Packing


Part Ⅱ: Product Features

1. Low Loss

① Magnetic flux leakage calculation and effective measures are adopted to reduce stray loss, effectively prevent local overheating and reduce the temperature rise of winding hot spots.

② Reasonable choice of coil wire to reduce winding eddy current losses, stray losses and other additional losses.


2


2. High Resistance to Short Circuit

① Dynamic analysis method is used for the analytical calculation of short-circuit mechanical forces.

② The low-voltage adopts self-adhesive transposition wire, which effectively increases the short-circuit resistance.


3


3. Low Noise

① Select high-quality core material, choose the appropriate magnetic flux density and self-oscillation frequency of the core.

② Adopt high precision jogging line with stepping shear and automatic stacking function to reduce burr of silicon steel sheet.


4


4. Low Temperature Rise

Perform oil flow distribution calculation, adopt reasonable oil flow distribution structure, and reduce the hot spot temperature rise and average temperature rise of winding.


5


Part Ⅲ: Product Main Parameter

SZ9(M)-1000~31500/35 Three-phase Oil-immersed Transformer with OLTC

Rated Capacity (kVA)

Rated Voltage and Tapping Range

Vector Group

No Load Losses (kW)

On Load Losses kW

Impedance Voltage %

No Load Current kW(9)

Weight (kg)

Outline Dimension
(mm)

Trail Distance
(mm)

HV

Tapping Range %

LV

Body

Oil

Gross

Transport

L×W×H

1000

30

±3×2.5

6.3, 6.6, 10.5, 11

Yd11

1.7

13.0

6.5

1.1

1930

1240

4600

3650

2850×1930×2430

1070×1070

1250

2.0

15.0

1.1

2200

1320

4950

3800

2900×1950×2450

1070×1070

1600

2.4

18.0

1

2550

1400

5300

3980

2950×1980×2490

1070×1070

2000

2.9

20.0

1

2775

1560

5965

4925

3010×2065×2540

1070×1070

2500

3.4

21.8

1

3300

1750

6950

5683

3035×2265×2610

1070×1070

3150

35
38.5

4.1

26.0

7

0.9

3770

1970

7900

6075

3160×2095×2640

1070×1070

4000

4.9

30.7

0.9

4520

2260

9110

7090

3295×2325×2890

1070×1070

5000

5.8

36.0

0.68

5620

2980

11825

9500

3900×3000×3050

1070×1475

6300

YNd11

7.0

39.0

7.5

0.68

6700

3340

13400

10350

3920×3020×3090

1070×1475

8000

9.84

44.0

0.6

8620

3670

16070

12500

4400×3200×3160

1475×1475

10000

11.6

51.0

0.6

9900

4000

18500

15400

4450×3520×3500

1475×1475

12500

13.68

60.5

8

0.56

11340

4365

21590

17800

4500×3600×3700

1475×1475

16000

16.46

74.0

0.54

14300

5400

22800

20100

4950×4100×3750

1475×1475

20000

19.46

87.14

0.54

15000

6100

30700

22800

5000×3930×3840

1475×1475

25000

23.4

104

0.5

19750

9300

38400

33800

5650×4150×3900

1475×1475

31500

27.5

123.1

0.45

23500

11500

45300

38800

5880×4300×3950

2040×1475


SZ10(M)-1000~31500/35 Three-phase Oil-immersed Transformer with OLTC

Rated Capacity (kVA)

Rated Voltage and Tapping Range

Vector Group

No Load Losses (kW)

On Load Losses kW

Impedance Voltage %

No Load Current kW(9)

Weight (kg)

Outline Dimension
(mm)

Trail Distance
(mm)

HV

Tapping Range %

LV

Body

Oil

Gross

Transport

L×W×H

1000

35

±3×2.5

6.3, 6.6, 10.5, 11

Yd11

1.5

12.3

6.5

1.1

2030

1290

4785

3795

2905×1970×2480

1070×1070

1250

1.8

14.2

1.1

2310

1370

5150

3950

2960×1990×2500

1070×1070

1600

2.2

17.0

1

2680

1460

5510

4130

3010×2020×2540

1070×1070

2000

2.6

19.2

1

2910

1620

6195

5120

3070×2105×2590

1070×1070

2500

3.1

20.6

1

3465

1820

7230

5910

3095×2310×2660

1070×1070

3150

35
38.5

3.7

24.6

7

0.9

3960

2050

8215

6310

3225×2140×2700

1070×1070

4000

4.4

29.0

0.9

4750

2350

9475

7375

3355×2375×2950

1070×1070

5000

5.2

34.0

0.8

5690

3010

11925

9600

3950×3050×3100

1070×1475

6300

6.3

36.6

0.8

6750

3370

13500

10400

3970×3070×3140

1070×1475

8000

YNd11

8.8

40.4

7.5

0.7

8670

3700

16170

12600

4450×3250×3210

1475×1475

10000

10.4

47.8

0.7

9970

4030

18600

15500

4500×3570×3550

1475×1475

12500

12.3

56.6

8

0.6

11410

4395

21690

17900

4550×3650×3750

1475×1475

16000

13.5

70.0

0.6

14370

5430

22900

20200

5000×4150×3800

1475×1475

20000

17.8

83.0

0.5

15090

6130

30800

22900

5050×3980×3890

1475×1475

25000

20.8

98.5

0.5

19820

9350

38500

33900

5700×4200×3950

1475×1475

31500

24.5

117.0

0.45

23370

11530

45400

38900

5700×4350×4000

2040×1475


SZ11(M)-1000~31500/35 Three-phase Oil-immersed Transformer with OLTC

Rated Capacity (kVA)

Rated Voltage and Tapping Range

Vector Group

No Load Losses (kW)

On Load Losses kW

Impedance Voltage %

No Load Current kW(9)

Weight (kg)

Outline Dimension
(mm)

Trail Distance
(mm)

HV

Tapping Range %

LV

Body

Oil

Gross

Transport

L×W×H

1000

35

±3×2.5

6.3, 6.6, 10.5, 11

Yd11

1.3

11.1

6.5

1.1

2125

1365

5060

4015

2965×2010×2530

1070×1070

1250

1.6

14.2

1.1

2420

1450

5445

4180

3015×2030×2550

1070×1070

1600

1.9

17.0

1

2805

1540

5830

4378

3070×2060×2590

1070×1070

2000

2.3

19.2

1

3050

1720

6560

5410

3130×2150×2640

1070×1070

2500

2.7

20.6

1

3630

1925

7645

6250

3160×2355×2715

1070×1070

3150

35
38.5

3.2

24.6

7

0.9

4150

2165

8690

6680

2865×2180×2750

1070×1070

4000

3.9

29.0

0.9

4970

2490

10020

7810

3425×2420×3010

1070×1070

5000

4.6

34.0

0.8

5720

3030

11975

9650

3960×3080×3130

1070×1475

6300

5.5

36.6

0.8

6780

3400

13560

10460

4000×3100×3170

1070×1475

8000

YNd11

7.7

40.4

7.5

0.7

8720

3730

16230

12630

4470×3100×3170

1475×1475

10000

9.1

47.8

0.7

9990

4050

18640

15540

4520×3590×3570

1475×1475

12500

10.8

56.6

8

0.6

11430

4415

21710

17920

4570×3070×3770

1475×1475

16000

12

70.0

0.6

14390

5450

22910

20220

5030×4170×3840

1475×1475

20000

16

83.0

0.5

15110

6150

30840

22940

5070×4000×3910

1475×1475

25000

18

98.0

0.5

19840

9370

38540

33940

5720×4220×3970

1475×1475

31500

21

117.0

0.45

23390

11550

45440

38910

5930×4370×4030

2040×1475


S9(M)-1000~31500/35 Three-phase Oil-immersed Transformer with NVTC

Rated Capacity (kVA)

Rated Voltage and Tapping Range

Vector Group

No Load Losses (kW)

On Load Losses kW

Impedance Voltage %

No Load Current kW(9)

Weight (kg)

Outline Dimension
(mm)

Trail Distance
(mm)

HV

Tapping Range %

LV

Body

Oil

Gross

Transport

L×W×H

1000

35

±5

3.15
6.3
10.5

Yd11

1.48

12.2

6.5

1

1880

970

3780

3080

2400×1620×2490

820×820

1250

1.8

14.7

0.9

2070

1010

4080

3320

2420×1720×2470

820×820

1600

2.13

17.6

0.85

2480

1090

4660

3830

2465×1830×2520

820×820

2000

2.61

19.4

0.75

2830

1200

5300

4330

2545×1680×2600

1070×1070

2500

3.15

20.7

0.75

3410

1330

6170

5060

2610×2050×2670

1070×1070

3150

35
38.5

3.87

24.3

7

0.7

3900

1520

7100

5710

2700×2090×2690

1070×1070

4000

4.64

28.8

0.7

4730

1750

6620

7020

2770×2300×2800

1070×1070

5000

5.49

33.0


0.6

5600

1950

9950

7860

2865×2425×2870

1070×1070

6300

6.6

36.9


0.6

6860

2320

11580

9460

3090×2285×3150

1475×1475

8000

±2×2.5

3.15
3.3
6.3
6.6
10.5
11

YNd11

9

40.5

7.5

0.55

8090

2500

14120

11500

3230×3050×3280

1475×1475

10000

10.6

47.7

0.55

9860

2850

16480

13500

3380×3150×3370

1475×1475

12500

12.6

56.7

8

0.5

10930

3250

18340

14890

3550×3190×3430

1475×1475

16000

15.3

69.3

0.5

13450

3750

22410

18350

3910×3350×3580

1475×1475

20000

18.1

83.7

0.5

14200

5700

28800

23500

3950×3400×3620

1475×1475

25000

21.5

99.0

0.5

19650

7130

35600

28000

4950×4550×3850

1475×1475

31500

25.7

118.8

0.4

26000

12200

42100

36000

5020×4700×3950

2040×1475


S10(M)-1000~31500/35 Three-phase Oil-immersed Transformer with NVTC

Rated Capacity (kVA)

Rated Voltage and Tapping Range

Vector Group

No Load Losses (kW)

On Load Losses kW

Impedance Voltage %

No Load Current kW(9)

Weight (kg)

Outline Dimension
(mm)

Trail Distance
(mm)

HV

Tapping Range %

LV

Body

Oil

Gross

Transport

L×W×H

1000

35

±5

3.15
6.3
10.5

Yd11

1.32

11.48

6.5

1

1980

1020

3970

3235

2440×1645×2540

820×820

1250

1.57

13.66

0.9

2180

1060

4280

3490

2470×1750×2550

820×820

1600

1.9

16.58

0.85

2610

1145

4890

4020

2515×1870×2550

820×820

2000

232

18.28

0.75

2980

1260

5565

4550

2600×1920×2650

1070×1070

2500

280

19.55

0.75

3580

1400

6480

5320

2670×2090×2750

1070×1070

3150

35
38.5

344

22.95

7

0.7

4095

1590

7455

5995

2755×2130×2750

1070×1070

4000

4.12

27.20

0.7

4970

1840

9050

7370

2830×2350×2855

1070×1070

5000

4.88

31.20

7.5

0.6

5880

2050

10450

8255

2830×2480×2930

1070×1070

6300

5.84

34.85

0.6

7200

2450

12160

9935

3150×2330×3220

1475×1475

8000

±2×2.5

3.15
3.3
6.3
6.6
10.5
11

YNd11

8

3825

0.55

8500

2530

14830

12075

3295×3110×3345

1475×1476

10000

9.44

45.05

0.55

10350

3000

17310

14180

3450×3210×3400

1475×1477

12500

11.2

53.55

8

0.5

11500

3400

19260

15635

3620×3255×3500

1475×1478

16000

13.6

65.5

0.5

14130

3940

23530

30240

3980×3420×3650

1475×1475

20000

16.08

79 05

0.5

14910

5990

28800

23500

4030×3470×3690

1475×1475

25000

19.12

93.5

0.5

20650

7490

35600

28000

5050×4640×3930

1475×1475

31500

22.8

112.2

0.4

27300

12810

42100

36000

5120×4800×4030

2040×1475


S11(M)-1000~31500/35 Three-phase Oil-immersed Transformer with NVTC

Rated Capacity (kVA)

Rated Voltage and Tapping Range

Vector Group

No Load Losses (kW)

On Load Losses kW

Impedance Voltage %

No Load Current kW(9)

Weight (kg)

Outline Dimension
(mm)

Trail Distance
(mm)

HV

Tapping Range %

LV

Body

Oil

Gross

Transport

L×W×H

1000

35

±5

3.15
6.3
10.5

Yd11

1.16

11.48

6.5

1

2070

1070

4160

3390

2500×1690×2590

1070×1070

1250

1.37

13.86

0.9

2280

1110

4490

3650

2520×1790×2590

1070×1070

1600

1.66

16.58

0.85

2730

1200

5130

4220

2560×1910×2620

1070×1070

2000

2.03

18, 28

0.75

3120

1320

5830

4770

2650×1955×2700

1070×1070

2500

2.45

19, 55

0.75

3750

1465

6790

5560

2720×2135×2780

1070×1070

3150

35
38.5

3.01

22.95

7

0.7

4290

1680

7810

6280

2800×2180×2800

1070×1070

4000

3.61

27.2

0.7

5200

1930

9490

7720

2880×2390×2910

1070×1070

5000

4.27

31.2

7.5

0.6

6160

2150

10950

8650

2980×2520×2990

1070×1070

6300

5.11

34.85

0.6

7550

2550

12740

10410

3215×23B0×3275

1475×1475

8000

±2×2.5

3.15
3.3
6.3
6.6
10.5
11

YNd11

7.00

38.25

0.55

8900

2750

15540

12650

3360×3170×3280

1475×1476

10000

8.26

45.05

0.55

10850

3140

18130

14850

3515×3280×3500

1475×1477

12500

9.80

53.55

8

0.5

12020

3580

20180

16380

3690×3320×3570

1475×1478

16000

11.90

65.45

0.5

14795

4125

24650

20185

4065×3490×3730

1475×1475

20000

14.07

79.05

0.5

15620

6270

31680

25850

4110×3550×3770

1475×1475

25000

16.73

93.50

0.5

21615

7840

39160

30800

5150×4730×4000

1475×1475

31500

19.95

112.2

0.4

28600

13420

46310

39600

5220×4890×4110

2040×1475


Part Ⅳ: Structural Diagram

12


Part Ⅴ: Quality Warranty

13


Part Ⅵ: Application

14


Part Ⅶ: Packaging and Transportation

15


Before packing the transformer, make a packing plan, and carry out packing according to the design scheme and plan when packing. The packing list corresponds to the materials in the box one to one. Pack the box in two copies, one in the packing box and the other nailed outside the packing box. Important parts and spare parts are packed in wooden boxes, and the box numbers are set in order.

The transformer is transported in bare installation, and the fuel tank is emptied before transport. It is tied to a transport vehicle by a wire rope, and the transport speed does not exceed 15km/h.

The terminal is guaranteed to have large-scale transformer lifting equipment, and the lashing is firm after loading to ensure safe and reliable transportation.


Part Ⅷ: Factory Tour

16


Part Ⅸ: Service Guarantee

1. To provide all technical information and drawings as per contract promptly. Everhydro is oblidged to invite client, if neccessory, to attend technical design review.

2. To carry out spot technical service as per client' s schedule, offer guideness for installation and commis- sioning according to technical information and drawings.

3. For relevant auxiliary equipment procured by customers. EverHydro will provide related technical information to meet requirement of equipment interface.

4. To execute stipulations in MOU or agreement signed by seller and buyer strictly.

5. To train staff from client for equipment installation commissioning, application, maintenance as stipulated in the contract.

6. To reinforce pre-sales, mid-sales, after-sales service to carry out "24-hour service", "service in advance", "overall process service", "lifelong service"in our manufacturing, installation, commissioning and maintance.

7. To meet spare parts requirements by customers at any time.


Part Ⅹ: FAQ

Q1: What is your MOQ?

A1: One set.


Q2: Is OEM/ODM available?

A2: Yes. All transformer can be customized by your requirements.


Q3: How long is your delivery time?

A3: It depends on your order quantity and generally it takes about 30~40days.


Q4: How long is the warranty?

A4: Within one year from sale date.