sales@hydgetpower.com    +86-21-58660061
enLanguage
Cont

Have any Questions?

+86-21-58660061

video

Non-Enveloped Dry Type Transformers Of1 0kV Level and Below

Non-encapsulated dry type transformers of 10kV level and below are made of dupont NOMEC insulation as the main insulation material. The products features are flame retardant, low loss, low noise, low local discharge, environmental protection, safe and reliable.
Send Inquiry

Product Introduction

Part Ⅰ: Non-Enveloped Dry Type Transformers Overview

Non-encapsulated dry type transformers of 10kV level and below are made of dupont NOMEC insulation as the main insulation material. The products features are flame retardant, low loss, low noise, low local discharge, environmental protection, safe and reliable. They are generally installed in power distribution rooms or box-type substations for lighting or power supply and the capacity is generally 2500kVA and below.


Non-enveloped dry type transformers of 10kV level and below
Product Attributes
Model No.SG9/SG10
ApplicationPower
CoilCore-type Transformer
Frequency50/60Hz
PhaseThree
Cooling MethodDry-type Transformer
Max. Ambient Temperature+40 °C
Max. daily average ambient temperature+30°C
Max.annual average ambient temperature+20°C
Min. temperature-5°C (indoor installation)
Operating Altitude≤1000m
StandardIEC 60076-11 :2004; ANSI, etc
Supply Ability & Additional Information
PackagingSeaworthy Packing
TransportationOcean
Supply AbilityHigh
Payment TypeL/C, T/T
Delivery Time60 Days
Place of OriginChina
PortChina Sea Port
IncotermFOB, CFR, CIF
Packaging & Delivery
Selling Units:Set/Sets
Package Type:Seaworthy Packing


Part Ⅱ: Product Features

1. Low Noise

① Adopt high-precision jogging line with stepping shear and automatic stacking function to reduce the burr of silicon steel sheet.

② The core stacking adopts "step full slope step lap joint technology" to improve the flux distribution at the joints.


2. Low Loss

① Optimize the transposition between the wires to make the cross-chain flux uniform and reduce the circulating losses caused by leakage magnetism.

② Implement slotting process on the core pulling plate to reduce the loss of core structural parts and prevent local overheating.


3. Environmental protection

① NOMEX insulation paper is non-toxic and non-hazardous, not polluting the environment

② Under the burning of high temperature open fire, SGB transformer almost no smoke generated


4. Low local discharge

Well-designed coil structure and vacuum pressure impregnation treatment process make SGB transformer partial discharge ≤5pC.


5. Flame retardant

① Wire insulation using the United States DuPont NOMEX insulation paper, with a stable molecular structure of the material, has superior high temperature resistance, flame retardant properties.

② Burning grade F1


6. Strong short circuit resistance

① High voltage coil adopts continuous pie type structure, with good mechanical strength.

② The low-voltage coil adopts foil structure, with uneven ampere-turn and small leakage, which reduces the axial mechanical force.


Part Ⅲ: Product Main Parameter

9 Series 10kV H-class Impregnated Insulated Dry-type Transformer
ModelRated Voltage and Tapping RangeVector GroupNo Load Losses (W)H-class Impregnated Insulated On Load Losses (W)No Load Current kW(9)Short-circuit Impedance
%
HVTapping Range %LV
(145℃)
SG9-1006; 6.3; 6.6; 10; 10.5; 11±5/±2×2.50.4Dyn11/
Yyn0
45017801.84
SG9-12553021001.6
SG9-16061024101.6
SG9-20070028701.4
SG9-25081031201.4
SG(B)9-31599039301.2
SG(B)9-40011004520.001.2
SG(B)9-50013105530.001.2
SG(B)9-630151066601
SG(B)9-6301460675016
SG(B)9-800171078801
SG(B)9-1000199092101
SG(B)9-1250235010980.01
SG(B)9-1600276013270.01
SG(B)9-2000340016370.00.8
SG(B)9-2500400019460.00.8
SG(B)9-1600276014660.018
SG(B)9-2000340018000.00.8
SG(B)9-2500400021400.00.8


10 Series 10kV H-class Impregnated Insulated Dry-type Transformer
ModelRated Voltage and Tapping RangeVector GroupNo Load Losses (W)H-class Impregnated Insulated On Load Losses (W)No Load Current kW(9)Short-circuit Impedance
%
HVTapping Range %LV
(145℃)
SG10-1006; 6.3; 6.6; 10; 10.5; 11±5/±2×2.50.4Dyn11/
Yyn0
40016901.84
SG10-12547019801.6
SG10-16054022801.6
SG10-20062027101.4
SG10-25072029601.4
SG(B)10-31588037301.2
SG(B)10-4009804280.001.2
SG(B)10-50011605230.001.2
SG(B)10-630134062901
SG(B)10-6301300640016
SG(B)10-800152074601
SG(B)10-1000177087601
SG(B)10-1250209010370.01
SG(B)10-1600245012580.01
SG(B)10-2000305015560.00.8
SG(B)10-2500360018450.00.8
SG(B)10-1600245013900.018
SG(B)10-2000305017110.00.8
SG(B)10-2500360020290.00.8


Part Ⅳ: Structural Diagram

4

5


SG (B) Series Body Dimension Table
ModelabcdefghijCopper barShell Size
SG10-100/10106065055055033516810011502852251550×1200×1800
SG10-160/10110065055055036018010512002902301550×1200×1800
SG10-200/10116065066055039019510012802902401550×1200×1800
SG10-250/10118076066066040020011513002902501550×1200×1800
SG(B)10-315/10118076066066040020011013603002501700×1200×1900
SG(B)10-400/10120078066066041020510014303002601750×1400×1900
SG(B)10-500/10127078066066043021511815003052651750×1400×1950
SG(B)10-630/10140078066066047523811514353152701850×1400×1950
SG(B)10-800/10148094066066049024521215903253001950×1400×2100
SG(B)10-1000/10155094082082052526321515703403102000×1500×2100
SG(B)10-1250/10160094082082053026524016953403052050×1500×2200
SG(B)10-1600/1017401200820107058529317317053553452200×1500×2200
SG(B)10-2000/10178012701070107059529818117903653502250×1500×2400
SG(B)10-2500/10192012701070107062531320520704303502400×1500×2600


Part Ⅴ: Quality Warranty

7


Part Ⅵ: Application

8


Part Ⅶ: Packaging and Transportation

9


Before packing the transformer, make a packing plan, and carry out packing according to the design scheme and plan when packing. The packing list corresponds to the materials in the box one to one. Pack the box in two copies, one in the packing box and the other nailed outside the packing box. Important parts and spare parts are packed in wooden boxes, and the box numbers are set in order.

The transformer is transported in bare installation, and the fuel tank is emptied before transport. It is tied to a transport vehicle by a wire rope, and the transport speed does not exceed 15km/h.

The terminal is guaranteed to have large-scale transformer lifting equipment, and the lashing is firm after loading to ensure safe and reliable transportation.


Part Ⅷ: Factory Tour

10


Part Ⅸ: Service Guarantee

1. To provide all technical information and drawings as per contract promptly. Everhydro is oblidged to invite client, if neccessory, to attend technical design review.

2. To carry out spot technical service as per client' s schedule, offer guideness for installation and commis- sioning according to technical information and drawings.

3. For relevant auxiliary equipment procured by customers. EverHydro will provide related technical information to meet requirement of equipment interface.

4. To execute stipulations in MOU or agreement signed by seller and buyer strictly.

5. To train staff from client for equipment installation commissioning, application, maintenance as stipulated in the contract.

6. To reinforce pre-sales, mid-sales, after-sales service to carry out "24-hour service", "service in advance", "overall process service", "lifelong service"in our manufacturing, installation, commissioning and maintance.

7. To meet spare parts requirements by customers at any time.


Part Ⅹ: FAQ

Q1: What is your MOQ?

A1: One set.


Q2: Is OEM/ODM available?

A2: Yes. All transformer can be customized by your requirements.


Q3: How long is your delivery time?

A3: It depends on your order quantity and generally it takes about 30~40days.


Q4: How long is the warranty?

A4: Within one year from sale date.


Hot Tags: non-enveloped dry type transformers of1 0kv level and below, China, suppliers, manufacturers, factory, price, made in China

Send Inquiry

(0/10)

clearall